Hey there, Water Cooled Chiller

If you’ve ever worked with water cooled chillers, you know that tiny bit of air in the system can turn into a massive headache real quick. It throws off cooling efficiency, makes weird gurgling noises, and even wears out parts way faster than it should. As someone who’s spent the last decade troubleshooting these things (and selling them, duh), I’ve seen way too many unit failures that could’ve been avoided with a simple purge. Today I’m walking you through exactly how to purge air from a water cooled chiller—no fancy jargon, just the real deal stuff I tell our customers when they call panicking at 2 a.m.
First, let’s get on the same page: why does air even get in there? Mostly it comes from when you first fill the system (air gets trapped in pipes and heat exchangers), or when you’re topping off water because of a leak, or even dissolved in the water itself that comes out of solution when the system heats up. That dissolved air is the sneaky stuff—It’s not just the big bubbles you can see, it’s the tiny micro-bubbles that stick to the evaporator tubes and act like insulation. That means your chiller has to work harder to cool the water, which hikes up energy bills and shortens its lifespan. No bueno.
Before you dive in, grab your basics: a pair of work gloves (you’ll be dealing with water that’s either super cold or hot, depending on where you are), a small bucket, a flathead screwdriver, and make sure the chiller is turned OFF. I know it’s tempting to just wing it while it’s running, but trust me—getting a burst of cold water or a surprise spray isn’t worth it. Also, check that the water level in the expansion tank is where it should be (your chiller manual will say, but usually it’s about 12-15 PSI). If it’s way off, fix that first before purging air—you don’t want to overfill later.
Now, let’s break this down step by step, starting with the easiest purge spots first, then moving to the tricky ones.
-
Bleed the High-Point Air Vents First
Every water cooled chiller system has these little brass or plastic vents (we call them “bleed valves”) at the highest points. These are your first stop. They’re usually on the top of the evaporator, the condenser, and any horizontal pipes that run uphill. Why high points? Because air rises, so that’s where all the big bubbles are hanging out.
Take your flathead screwdriver, slowly turn the vent counter-clockwise just a quarter turn—don’t yank it open all the way, that’ll cause a geyser and make a mess. You’ll hear a hissing sound first—that’s the air escaping. Keep it open until all the hissing stops and a steady, thin stream of water comes out, no sputtering. Then close the vent tight, clockwise. Do this on every single high-point vent. I see people skip one all the time, and that’s why their cooling is still garbage a week later. Pro tip: mark which vents you did with a sticky note if you’re working alone, so you don’t miss any. -
Bleed the Pump Air Vent
The chiller’s water pump is another spot where air loves to hide. Most pumps have a small bleed screw right on the top housing. This is super important because if the pump has air, it won’t circulate water properly—you’ll get dead zones in the system, and the chiller will trip on high discharge pressure.
Same drill here: turn the screw slowly. Again, listen for the hissing. Once you get a solid flow of water, close it up. This only takes like 30 seconds, but don’t skip it. I’ve had a customer call saying their chiller was freezing up, and it turned out they forgot the pump vent. Fixed in 2 minutes. -
Purge the Expansion Tank
Wait, expansion tank? Yeah, that rubber or steel tank that balances water pressure is a secret air trap. Sometimes air accumulates in the bladder (if it’s a bladder tank) or the tank itself, which makes it not work right. If your system has a diaphragm tank, there’s usually a tiny air valve on the top, like a bike tire valve. Turn the chiller off, make sure the pressure is at the recommended level (again, manual is your friend), then briefly press the valve core to let any trapped air out—don’t do it for more than a second, you don’t want to lose too much water. If it’s a non-bladder tank, there might be a drain valve on the bottom; open it a tiny bit to let a little water run out, which will push air up and out, then close it. -
Run the System and Purge Micro-Air (The Tricky Stuff)
Okay, so you’ve done all the big vents, but that’s probably not enough. The micro-bubbles are still in the water, and they’ll come out when the system is running. Now’s the time to start the chiller, but on LOW load. Don’t turn it on full blast—run it at 20-30% capacity for 15-20 minutes. This lets the water circulate slowly, giving the micro-bubbles time to rise to the vents you already opened.
While it’s running, go back through all the vents one more time. You might hear a little more hissing this time, that’s the micro-bubbles escaping. Do this 2-3 times until all you get is clear water no sputtering. Also, keep an eye on the pressure gauge on the chiller panel. If it drops after purging, you can top off the water with demineralized water (tap water has minerals that will gunk up the heat exchanger, trust me) to get it back to the right PSI. -
Final Check for Hidden Air
After you’re done, wait an hour, then check again. Sometimes air gets into the pipes when the system heats up, especially if you have long runs. If you start hearing gurgling noises from the pipes or the chiller trips on low temperature, you missed a spot. Don’t panic—just go back to the vents and bleed again.
Now, let’s talk about common mistakes I see people make all the time. First, opening the vents too wide. That causes water to spray all over electrical parts, which is a fire hazard and can ruin your chiller. Take it slow, quarter turns only. Second, not using demineralized water. Tap water has calcium and chlorine, which build up on the heat exchanger over time and make your chiller less efficient. We always tell our customers to buy pre-mixed demin water for top-offs. Third, skipping the pump vent. That’s like forgetting to check your oil before a road trip—you’re asking for trouble. Fourth, running the chiller at full load right away. That just stirs up the micro-bubbles and makes them harder to get out.
Wait, also—what if you have a chiller with an automatic air vent? A lot of newer models have these instead of manual vents. Do you still need to purge? Yeah, sometimes the automatic ones get clogged with gunk, so you might need to manually open them to clear the blockage. They’re usually on the same high points, just a plastic cap you can twist off gently.
Another thing: if you just installed a new chiller, you might need to purge more than usual. Install lines can have extra air trapped in them. Plan to do two full purge cycles in the first week after installation to make sure all the air is out.
Now, how often should you purge air? It depends on how much you use the chiller, but at least once a year before the cooling season starts. Also, if you notice a drop in cooling performance, weird noises, or pressure swings, purge right away—don’t wait for it to break down.
As a chiller supplier, I can’t stress enough how important proper air purging is. We’ve had customers come to us after trying to do it themselves and messing up, and it’s way more expensive to fix a broken chiller than to do the purge right the first time. If you’re not comfortable doing this yourself, just reach out—we have techs on call who can come out and do it for you, no hassle.
At the end of the day, purging air from a water cooled chiller isn’t rocket science. It’s just paying attention to the small details, taking it slow, and not skipping steps. The time you spend doing it saves you hundreds (or thousands) in energy bills and repair costs later.

If you’re dealing with persistent air issues or need a new chiller that’s built to hold air out better for longer, feel free to get in touch to chat about your needs. We’re here to help you keep your system running smooth all year round.
Air cooled Screw Chiller REFERENCES
- Carrier Commercial HVAC: Water Cooled Chiller Maintenance Guide
- ASHRAE Handbook – HVAC Systems and Equipment
- Trane Chiller Operation and Troubleshooting Manual
Guangdong Head-Power Air-Conditioning Co., Ltd.
Guangdong Head-Power Air-Conditioning Co., Ltd. is one of the most professional water cooled chiller manufacturers and suppliers in China, specialized in providing high quality products made in China. We warmly welcome you to buy customized water cooled chiller at low price from our factory. Contact us for quotation.
Address: Shiling Chenbian Section, 321 National Highway, Shishan Town, Nanhai District, Foshan, Guangdong, China.
E-mail: info@china-headpower.com
WebSite: https://www.headpowerac.com/